Focal points: Self-completion questionnaires were used to determine issues with compliance surrounding the use of oral chemotherapy in haematology patients Forty-two patients were identified of which 40 responded over a two-month period Twenty-one respondents (52.5 per cent) indicated that they experienced difficulties in taking their medication Difficulties were not apparently related to the time of dosing; the size of dose units (hydroxyurea) and foil packed agents caused particular difficulties

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Helicobacter pylori is one of the most common pathogenic bacterial infections, colonising an estimated half of all humans. It is associated with the development of serious gastroduodenal disease - including peptic ulcers, gastric lymphoma and acute chronic gastritis. Current recommended regimes are not wholly effective and patient compliance, side-effects and bacterial resistance can be problematic. Drug delivery to the site of residence in the gastric mucosa may improve efficacy of the current and emerging treatments. Gastric retentive delivery systems potentially allow increased penetration of the mucus layer and therefore increased drug concentration at the site of action. Proposed gastric retentive systems for the enhancement of local drug delivery include floating systems, expandable or swellable systems and bioadhesive systems. Generally, problems with these formulations are lack of specificity, limited to mucus turnover or failure to persist in the stomach. Gastric mucoadhesive systems are hailed as a promising technology to address this issue, penetrating the mucus layer and prolonging activity at the mucus-epithelial interface. This review appraises gastroretentive delivery strategies specifically with regard to their application as a delivery system to target Helicobacter. As drug-resistant strains emerge, the development of a vaccine to eradicate and prevent reinfection is an attractive proposition. Proposed prophylactic and therapeutic vaccines have been delivered using a number of mucosal routes using viral and non-viral vectors. The delivery form, inclusion of adjuvants, and delivery regime will influence the immune response generated. © 2005 Bentham Science Publishers Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Currently available treatments for insulin-dependent diabetes mellitus are often inadequate in terms of both efficacy and patient compliance. Gene therapy offers the possibility of a novel and improved method by which exogenous insulin can be delivered to a patient. This was approached in the present study by constructing a novel insulin-secreting cell line. For the purposes of this work immortalized cell lines were used. Fibroblasts and pituitary cells were transfected with the human preproisinulin gene to create stable lines of proinsulin- and insulin-secreting cells. The effect of known β-cell secretagogues on these cells were investigated, and found mostly to have no stimulatory effect, although IBMX, arginine and ZnSO4 each increased the rate of secretion. Cyclosporin (CyA) is currently the immunosuppresant of choice for transplant recipients; the effect of this treatment on endogenous β-cell function was assessed both in vivo and in vitro. Therapeutic doses of CyA were found to reduce plasma insulin concentrations and to impair glucose tolerance. The effect of immunoisolation on insulin release by HIT T15 cells was also investigated. The presence of an alginate membrane was found to severely impair insulin release. For the first implantation of the insulin-secreting cells, the animal model selected was the athymic nude mouse. This animal is immunoincompetent, and hence the use of an immunosuppressive regimen is circumvented. Graft function was assessed by measurement of plasma human C peptide concentrations, using a highly specific assay. Intraperitoneal implantation of genetically manipulated insulin-secreting pituitary cells into nude mice subsequently treated with a large dose of streptozotocin (STZ) resulted in a significantly delayed onset of hyperglycaemia when compared to control animals. Consumption of a ZnSO4 solution was shown to increase human C peptide release by the implant. Ensuing studies in nude mice examined the efficacy of different implantation sites, and included histochemical examination of the tumours. Aldehyde fuchsin staining and immunocytochemical processing demonstrated the presence of insulin containing cells within the excised tissue. Following initial investigations in nude mice, implantation studies were performed in CyA-immunosuppressed normal and STZ-diabetic mice. Graft function was found to be less efficacious, possibly due to the subcutaneous implantation site, or to the immunosuppresive regimen. Histochemical and transmission electron microscopic analysis of the tumour-like cell clusters found at autopsy revealed necrosis of cells at the core, but essentially normal cell morphology, with dense secretory granules in peripheral cells. The thesis provides evidence that gene therapy offers a feasibly new approach to insulin delivery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cardiovascular disease (CVD) continues to be one of the top causes of mortality in the world. World Heart Organization (WHO) reported that in 2004, CVD contributed to almost 30% of death from estimated worldwide death figures of 58 million[1]. Heart failure treatment varies from lifestyle adjustment to heart transplantation; its aims are to reduce HF symptoms, prolong patient survival and minimize risk [2]. One alternative available in the market for HF treatment is Left Ventricular Assist Device (LVAD). Chronic Intermittent Mechanical Support (CIMS) device is a novel (LVAD) heart failure treatment using counterpulsation similar to Intra Aortic Balloon Pumps (IABP). However, the implantation site of the CIMS balloon is in the ascending aorta just distal to aortic valve contrasted with IABP in the descending aorta. Counterpulsation coupled with implantation close to the aortic valve enables comparable flow augmentation with reduced balloon volume. Two prototypes of the CIMS balloon were constructed using rapid prototyping: the straight-body model is a cylindrical tube with a silicone membrane lining with zero expansive compliance. The compliant-body model had a bulging structure that allowed the membrane to expand under native systolic pressure increasing the device’s static compliance to 1.5 mL/mmHg. This study examined the effect of device compliance and vascular compliance on counterpulsating flow augmentation. Both prototypes were tested on a two-element Windkessel model human mock circulatory loop (MCL). The devices were placed just distal to aortic valve and left coronary artery. The MCL mimicked HF with cardiac output of 3 L/min, left ventricular pressure of 85/15 mmHg, aortic pressure of 70/50 mmHg and left coronary artery flow rate of 66 mL/min. The mean arterial pressure (MAP) was calculated to be 57 mmHg. Arterial compliance was set to be1.25 mL/mmHg and 2.5 mL/mmHg. Inflation of the balloon was triggered at the dicrotic notch while deflation was at minimum aortic pressure prior to systole. Important haemodynamics parameters such as left ventricular pressure (LVP), aortic pressure (AoP), cardiac output (CO), left coronary artery flowrate (QcorMean), and dP (Peak aortic diastolic augmentation pressure – AoPmax ) were simultaneously recorded for both non-assisted mode and assisted mode. ANOVA was used to analyse the effect of both factors (balloon and arterial compliance) to flow augmentation. The results showed that for cardiac output and left coronary artery flowrate, there were significant difference between balloon and arterial compliance at p < 0.001. Cardiac output recorded maximum output at 18% for compliant body and stiff arterial compliance. Left coronary artery flowrate also recorded around 20% increase due to compliant body and stiffer arterial compliance. Resistance to blood ejection recorded highest difference for combination of straight body and stiffer arterial compliance. From these results it is clear that both balloon and arterial compliance are statistically significant factors for flow augmentation on peripheral artery and reduction of resistance. Although the result for resistance reduction was different from flow augmentation, these results serves as an important aspect which will influence the future design of the CIMS balloon and its control strategy. References: 1. Mathers C, Boerma T, Fat DM. The Global Burden of disease:2004 update. Geneva: World Heatlh Organization; 2008. 2. Jessup M, Brozena S. Heart Failure. N Engl J Med 2003;348:2007-18.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and Objective: To maximise the benefit from statin therapy, patients must maintain regular therapy indefinitely. Non-compliance is thought to be common in those taking medication at regular intervals over long periods of time, especially where they may perceive no immediate benefit (News editorial, 2002). This study extends previous work in which commonly held prescribing data is used as a surrogate marker of compliance and was designed to examine compliance in those stabilised on statins in a large General Practice. Design: Following ethical approval, details of all patients who had a single statin for 12 consecutive months with no changes in drug, frequency or dose, between December 1999 and March 2003, were obtained. Setting: An Eastern Birmingham Primary Care Trust GP surgery. Main Outcome Measures: A compliance ratio was calculated by dividing the number of days treatment by the number of doses prescribed. For a once daily regimen the ratio for full compliance_1. Results: 324 patients were identified. The average compliance ratio for the first six months of the study was 1.06 ± 0.01 (range 0.46 – 2.13) and for the full twelve months was 1.05 ± 0.01 (range 0.58 – 2.08). Conclusions: The data shown here indicates that as a group, long-term, stabilised statin users appear compliant. However, the range of values obtained show that there are identifiable subsets of patients who are not taking their therapy as prescribed. Although the apparent use of more doses than prescribed in some patients may result from medication hording, this cannot be the case in the patients who apparently take less. It has been demonstrated here that the compliance ratio can be used as an early indicator of problems allowing targeted compliance advice can be given where it will have the most benefit. References: News Editorial. Pharmacy records could be used to enhance statin compliance in elderly. Pharm. J. 2002; 269: 121.